Packaging Details : Carton Box for Outer, Gift Box for Unit
Payment Terms : T/T, Paypal, Western Union
Place of Origin : China
Trade Terms : FOB, CFR, CIF
Production Capacity : 120000 PCS/Month
Model Number : YH3002
Brand Name : YH
Standard : 280*260*125 mm
Min. order : 1 Pieces
Main Markets : Global
Type : Test and Measurement Instruments
Category : Frequency Meters
RA 3pole method: | |
Testing voltage | AC 20/48V |
Testing frequency | 94Hz/105Hz/111Hz/128Hz/AFC(MeterA/Meter B) |
94 Hz/128 Hz(Meter C) | |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B, Meter C) | |
Test duration | 26s |
Probe resistance Rs | < 100 kOhms |
Auxiliary earthing resistance Rh | < 100 kOhms |
Re resolution | 0.001 Ohms |
Re Measuring range | 0.02Ohms~300kOhms ± (5%rdg+10d) (Meter A) |
0.1Ohms~30kOhms ± (5%rdg+10d) (Meter B) | |
0.1Ohms~20kOhms ± (5%rdg+10d) (Meter C) | |
Ust | < 24V |
Fst | 16 ~ 400 Hz |
RA 4 pole method: | |
Testing voltage | AC 20/48V |
Testing frequency | 94Hz/105Hz/111Hz/128Hz/AFC(Meter A / Meter B ) |
94 Hz/128 Hz(Meter C) | |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B, Meter C) | |
Test duration | 30s |
Probe resistance Rs | < 100 kOhms |
Auxiliary earthing resistance Rh | < 100 kOhms |
Re resolution | 0.001 Ohms |
RE Measuring range | 0.02Ohms~300kOhms: ± (5%rdg+10) (Meter A) |
0.1Ohms~30kOhms: ± (5%rdg+10) (Meter B) | |
0.1Ohms~20kOhms: ± (5%rdg+10) (Meter C) | |
Ust | < 24V |
Fst | 16 ~ 400 Hz |
RA 3pole method(Meter A/Meter B): | |
Testing voltage | AC 20/48V |
Testing frequency | 94Hz/105Hz/111Hz/128Hz/AFC |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B) | |
Test duration | 26s |
Probe resistance Rs | < 100 kOhms |
Auxiliary earthing resistance Rh | < 100 kOhms |
Re resolution | 0.001 Ohms |
Re Measuring range | 0.02Ohms~20kOhms ± (5%rdg+10d) (Meter A) |
0.1Ohms~10kOhms ± (5%rdg+10d) (Meter B) | |
Ust | < 24V |
Fst | 16 ~ 400 Hz |
RA 4pole method(Meter A/Meter B): | |
Testing voltage | AC 20/48V |
Testing frequency | 94Hz, 105Hz, 111Hz, 128Hz /AFC |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B) | |
Test duration | 26s |
Probe resistance Rs | < 100 kOhms |
Auxiliary earthing resistance Rh | < 100 kOhms |
Re resolution | 0.001 Ohms |
RE Measuring range | 0.02Ohms~20kOhms ± (5%rdg+10d) (Meter A) |
0.1Ohms~10kOhms ± (5%rdg+10d) (Meter B) | |
Ust | < 24V |
Fst | 16 ~ 400 Hz |
Test of earthing-resistance with stake(Meter A/Meter B): | |
Testing voltage | AC 48V |
Testing frequency | 94Hz/105Hz/111Hz/128Hz/AFC |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B) | |
Test duration | 26s |
Re resolution | 0.001 Ohms |
RE Measuring range | 0.02~150Ohms ± (10%rdg+10d) |
0.1~150Ohms ± (10%rdg+10d) | |
Ust | < 24V |
Fst | 16 ~ 400 Hz |
Soil resistivity test Ï : | |
Testing voltage | AC 20/48V |
Testing frequency | 94Hz/105Hz/111Hz/128Hz/AFC(Meter A/Meter B) |
94 Hz/128 Hz(Meter B) | |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B/Meter C) | |
Test duration | 26s |
Ï resolution | 0.001 OHMS· m |
Ï Measuring range | 0.02 OHMS· m ~1000 kOHMS· m ± (5%rdg+10d) |
2pole R~ : | |
Testing voltage | A C 20V |
Testing frequency | 94Hz/105Hz/111Hz/128Hz/AFC(Meter A/Meter B) |
94 Hz/128 Hz(Meter C) | |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B / Meter C) | |
Test duration | 26s |
R~ resolution | 0.001 OHMS |
R~ Measuring range | 0.02OHMS~300kOHMS ± (5%rdg+10d) (Meter A) |
0.1OHMS~30kOHMS ± (5%rdg+10d) (Meter B) | |
0.1OHMS~20kOHMS ± (5%rdg+10d) (Meter C) | |
Ust | < 24V |
Fst | 16 ~ 400 Hz |
2pole R (Meter A/Meter B): | |
Testing voltage | DC 20V |
Short-circuit current | 250 mA (Meter A) |
100 mA (Meter B) | |
Test duration | 26s |
R resolution | 0.001 OHMS |
R Measuring range | 0.02OHMS~3kOHMS ± (5%rdg+10d) (Meter A) |
0.1OHMS~3kOHMS ± (5%rdg+10d) (Meter B) | |
Ust | ≤ 3V |
Fst | 16 ~ 400 Hz |
4pole R (Meter A/Meter B): | |
Testing voltage | DC 20V |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B) | |
Test duration | 26s |
R resolution | 0.001 OHMS |
R Measuring range | 0.02OHMS~3kOHMS ± (5%rdg+10d) (Meter A) |
0.1OHMS~3kOHMS ± (5%rdg+10d) (Meter B) | |
Ust | ≤ 3V |
Fst | 16 ~ 400 Hz |
Compensation for Rk test-wire resistance (2-pole method): | |
Testing voltage | AC 20/48V |
Testing frequency | 94Hz/105Hz/111Hz/128Hz/AFC(Meter A / Meter B) |
94 Hz/128 Hz (Meter C) | |
Short-circuit current | 250mA(Meter A) |
100mA(Meter B / Meter C) | |
Test duration | 26s |
R resolution | 0.001 OHMS |
R Measuring range | 0.02~30.00OHMS ± (3%rdg+10d) (Meter A) |
0.1~30.00OHMS ± (3%rdg+10d) (Meter B / Meter C) | |
Ust | < 24V |
Fst | 16 ~ 400 Hz |
Interfering voltage/current/frequency : | |
Test method | Measuring range |
Interference-voltage test |
± 1VDC~± 50VDC/1VAC~50VAC (Resolution: 0.1V; Accuracy: ± (5%rdg+5d)) |
Interference-current test |
20mA~2A (Resolution: 1mA; Accuracy: ± (5%rdg+5d)(Meter A/Meter B)) |
Interference-frequency test |
16 ~ 400 Hz (Resolution: 1Hz; Accuracy: ± (1%rdg+10d)) |
![]() |
USB Interface Intelligent Dual Jaw Ground Resistance Tester (YH3002) Images |
Friendly Links: www.everychina.com
Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们